Showing results: 31 - 45 of 126 items found.
-
GF102 -
Beijing GFUVE Electronics Co.,Ltd.
The GF102 is used to test single phase energy meter error. Adopt mature signal synthetic and power amplifier technology, high precision 500V voltage and 120A current output, accuracy 0.05%, automatically test all kinds of single phase enegy meter.
-
SUG255 -
Lisun Electronics Inc.
The Impulse Withstand Voltage Tester (or High Voltage Surge Generator), it is according to IEC255-5, IEC60060, IEC60065, GB14711, GBT17215.301 and GBT17215.322. It is suitable for doing all kinds of electrical and electronic products (such as energy meter, household appliances, low voltage electrical appliances and small power motor) insulation performance test.
-
SSG 2100 -
BAUR Prüf- und Messtechnik GmbH
Cable fault location with the BAUR SSG 2100. Surge voltage generators are used for pre-location and pinpointing of high- and low-resistive as well as intermittent faults in power cables. The energy stored in a high-voltage capacitor is released at regular intervals or as DC voltage. The thus generated acoustic signal at the fault position can be recorded with a ground microphone and a universal receiver.* High surge voltage up to 32 kV* Continuously adjustable voltage* Voltage monitoring through kV meters with 3 measuring ranges* Automatic discharge unit
-
SSG 1100 -
BAUR Prüf- und Messtechnik GmbH
Cable fault location with the BAUR SSG 1100. Surge voltage generators are used for pre-location and pinpointing of high- and low-resistive as well as intermittent faults in power cables. The energy stored in a high-voltage capacitor is released at regular intervals or as DC voltage. The thus generated acoustic signal at the fault position can be recorded with a ground microphone and a universal receiver.* High surge voltage up to 32 kV* Continuously adjustable voltage* Voltage monitoring through kV meters with 3 measuring ranges* Automatic discharge unit
-
SSG 1500 -
BAUR Prüf- und Messtechnik GmbH
Cable fault location with the BAUR SSG 1500. Surge voltage generators are used for pre-location and pinpointing of high- and low-resistive as well as intermittent faults in power cables. The energy stored in a high-voltage capacitor is released at regular intervals or as DC voltage. The thus generated acoustic signal at the fault position can be recorded with a ground microphone and a universal receiver.* High surge voltage up to 32 kV* Continuously adjustable voltage* Voltage monitoring through kV meters with 3 measuring ranges* Automatic discharge unit
-
SG7501 -
Shanghai Jiuzhi Electric Co., Ltd.
SG7501 Oil Dissipation Factor and Resistivity Meter is used to measure dissipation factor, dielectric constant and resistivity for oil. The set is all-in-one structure, with internal oil cup, temperature control, AC bridge, high resistance meter, AC/DC test voltage and standard capacitor etc.
-
ST1000 -
Shenzhen Star Instrument Co., Ltd.
The ST1000 three-phase reference meter incorporates high-precision A/D converter, DSP, wide-range measuring and embedding industrial PC technologies. It has a high accuracy of class 0.01. The voltage measuring range (phase voltage): 1V~480V, current measuring range: 1mA~120A.
-
DM3420 -
Labfacility Ltd.
The DM3420 panel meter accepts Voltage and Current process signals and displays the process value on a high efficiency daylight readable LED display. A built in transmitter power supply is also provided.
-
AJIT Electronics Co.
This is a common test panel for distribution/ power transformers of different specifications. The user can perform most of the factory tests, as per the relevant IS standard for the transformers. The panel consists of power analyser, meters for high voltage test, meters for induced voltage test etc, control for all the tests, protection and interlock circuits so that a single panel can be used to conduct a number of tests using only one dimmerstat and the associated devices
-
N1427B -
Keysight Technologies
The N1427B is designed to operate specifically with the B2985B/87B Electrometer/High Resistance Meter. It comes with a separate triaxial (special screw-type) female connector and a High Voltage BNC (special type) female connector. This allows terminal configuration to be converted to any other configuration. Therefore, custom test fixture can easily be constructed. The N1413A High Resistance Meter Fixture Adapter is required to connect the N1427B to the B2985B/87B.
-
N1427A -
Keysight Technologies
The N1427A is designed to operate specifically with the B2985B/87B Electrometer/High Resistance Meter. It comes with a separate triaxial (special screw-type) female connector and a High Voltage BNC (special type) female connector. This allows terminal configuration to be converted to any other configuration. Therefore, custom test fixture can easily be constructed. The N1413A High Resistance Meter Fixture Adapter is also required to connect the N1427A to the B2985B/87B.
-
SVP Neon Equipment
The SVP Medium Accuracy Vacuum Gauge is based on the Hastings 0-1,000 mtorr (micron) meter assembly. SVP has chosen Hastings instruments for their quality and dependability when used in close proximity to high voltage.
-
LSP-5KVA -
Lisun Electronics Inc.
• Circuit Type: (IGBT) MPWM Pulse Duration Modulation • Input: 1 Phase 220V±10%, 50Hz/60Hz±5% • Output Voltage: HIGH/LOW Adjustable 1)1 Phase Voltage Range: (HIGH)0~300V, (LOW)0~150V 2) Nominal Voltage: +10%~+25%, -10%~-30% • Output Frequency: 50Hz, 60Hz, adjustable between 45 and 70 Hz, 400Hz • Load Voltage Stabilization Rate: ≦0.5% • Frequency Stabilization Rate: 0. 1% (Fix Point 50Hz, 60Hz and 400Hz) • Wave Distortion Rate: ≦2% (Resistor Load); Efficiency: ≧85% • Output Instruments: Frequency Indicator, 4-digits RMS digital frequency indicator, resolution is 0.1Hz Voltage Meter, 4-digits RMS digital voltage meter, resolution 0.1V Ampere Meter, 4-digist RMS digital ampere meter, resolution 1Ma Power Indicator, 4-digits RMS digital power indicator, resolution 1W Power Factor Meter Resolution 0.001 • Protective Devices: Over load, short circuit, over voltage, over current, over temperature protective and alarm devices • Operating Environment: Temperature 0~40℃ Relative Humidity 0~90%
-
Voltstik -
SensorLink
The Voltstik is a distribution voltage voltmeter designed for use on lines and in substations. This meter is employed onto a line by using a hot stick and universal chuck adapter. It is capable of measuring voltage phase to phase, and phase to ground. This high impedance instrument is an excellent choice for solving multiple problems associated with operating a medium voltage system. Its key applications are defined under three groups, safety confirmation of the voltage present, troubleshooting voltage problems, and phasing.
-
LAB Series -
Aplab Limited
- 19” Rack Adaptable- Constant Voltage / Constant Current Operation- Two Digital Meters – 3 Digit DPMs- Phase Controlled PreRegulation Plus Linear PostRegulation- Remote Sensing Facility- High Stability and Close Regulation ±0.01%OPTIONS AT EXTRA COSTa) Presetting Facilityb) Over Voltage Protectionc) 19” Rack Mountingd) Analog programming &monitoring for Voltage &Current.